High Availability Computing Solutions - Take a Look
|
|
|
|
|
          

 
 
Jasper Electronic
Compact PCI Power Supply
200 Watt, AC Input
Model # PCI204-1022-4 (M1099)

FEATURES:

  • STANDARD PCI OUTPUT VOLTAGES: 5.0V, 3.3V, + 12.0V, WITH VARIABLE CURRENTS
  • HOT SWAP, N + 1 REDUNDANT WITH INTERNAL OR-ING DIODES
  • .99 POWER FACTOR CORRECTED AC 90-264V INPUT
  • CURRENT SHARING ON 5.0V AND 3.3V OUTPUTS
  • STANDARD 47 PIN OR 32 PIN DIN CONNECTOR CONFIGURATIONS
  • COMPLIES WITH ALL REQUIREMENTS OF PICMG POWER INTERFACE SPECIFICATIONS

Specifications:

-INPUT-

Voltage/Current .............. AC 90-264V, 3.2A max, 47-63Hz, 1 Phase

Fusing ............................ Internal line fuse provided, non-user serviceable.

                                        AC- 3.15A, 250V; DC- 10.0A.

Power Factor.................. 0.99 line PFC typical at AC 115V, full load.

Inrush Current ................ Thermistor soft start. ~25ºC AC cold start current

                                         15Apk @ AC 115V; 30Apk @ AC 230V.

Transient Protection ....... MOV. Withstands transients as specified by

                                        IEEE C62.41 3KV (differential and common mode).

EMI Filtering ................... Meets IFCC Level B, and EN 55022 Level B

                                         (conducted).

Efficiency........................ 70% typical at AC 115V, full load.

Redundant/Hot Swap ..... Full power N+1 redundant, hot swap capable.

-OUTPUTS-

Model

V/A  V1

V2

V3

V4

PCI204-10222

5.0/33

3.3/33

+12/6.0

- 12/1.0


Line Regulation .............. At the Sense Point, Over Full Input Range <±1%,

                                        sense leads connected.

Load Regulation ............. Output voltage droops with increasing load.

Minimum Loading........... 5% minimum on V1.

Stability .......................... Output drift <±0.2% after 20 minute warm-up.

Temp. Coefficient ........... <±0.02%/ºC, 0º - 50ºC, after 20 minute warm- up.

                                       Dynamic Response ........Less than 3% deviation with a 25% load change

                                        at 1A/µsec. Output returns to within 1% in less

                                        than 300µsec.

                                        Ripple and Noise

(PARD)........................... For all outputs, 50mV max or 1% peak-to-peak

                                        nominal, which ever is greater, DC to 20MHz

                                        bandwidth with a coaxial probe and 0.1µF/22µF

                                        capacitors at the output terminals.

Current Sharing/

Parallel N+1 Operation ... V1, V2, V3 Outputs. Droop method standard.

                                        Optional single wire design in development.

                                        Consult factory for availability.

Remote Sense................ V1, V2, V3 outputs compensate for up to 0.25V

                                        total line drop in the load cables. Outputs are

                                        internally sensed if leads are opened.

Hold-Up Time ................. Outputs remain in regulation >15msec minimum

                                        following loss of AC power at low line, full load.

Over Current/Short

Circuit Protection............ Current limit on all outputs. Automatic recovery

                                        when overload is removed.

Over Temperature

Protection....................... Internal temperature sensing. Causes all outputs

                                        to shut down. Automatic recovery.

Over/Under Shoot .......... None at turn-on or turn-off.

Under Voltage Warning ..Any output dropping below 10% of nominal

                                        triggers the power fail warning signal.

Over Voltage

Protection .......................Non-crowbar type. Any output that exceeds

                                        25% ±10% of nominal Vout will cause all outputs

                                        to latch off. Remote inhibit, enable or input

                                        recycle required to reset.

-SIGNALS, INDICATORS and CONTROLS-

Remote Enable...............Enabled by closed circuit or TTL logic 0.

                                       Disabled by open circuit or TTL logic 1.

Power Fail Warning .......Loss of input AC causes a TTL compatible signal to go low >4msec prior to any output dropping out of regulation. At AC turn-on, signal stays low until all outputs are in regulation. PF signal also triggered by an under voltage condition on any output.

LED Indicator..................Dual LEDs. Green indicates input power ON and outputs within regulation. Off or Amber  indicates input and/or output power fault.

-OPERATING ENVIRONMENT-

Operating Temperature ..0º – 50ºC ambient at full load, with specified airflow.

Cooling ...........................A minimum of 15 cfm / 400 lfm direct forward airflow required to achieve full rated power and specified MTBF. Consult factory for derating guidelines with reduced or reversed airflow.

Relative Humidity............Up to 90% RH, non-condensing.

Operational Vibration ......0.75G peak, 5 – 500Hz along three orthogonal axis.

Storage Temperature......-40º to 85ºC.

Altitude ...........................Operating to 10,000 ft; Storage to 30,000 ft.

MTBF .............................Designed for 150,000 hrs at 25ºC.

-INTERCONNECT-

I/O Connectors. Refer to JE Outline Configuration Drawing #02102-000 or the chart in this catalog for pin function identification-

47 Circuit ....................Positronic Ind. P/N PCIH47M400A1.

                                    Mates with PI P/N PCIH47F300A1.

32 Circuit (AC only).....Contact factory.

Note: Use of the specified mating connector is required to insure proper "make/break" sequential contact sequence.

-MECHANICAL-

Outline............................3U x 8HP front panel. Refer to JE Outline Dwg #02102-000 or the Mechanical Outline in this catalog. Complies with all current PICMG ® CompactPCI PSU specifications.

Retaining Latches...........Supplied with a single Rittal #3686.135 Type VII (Telecom) Lower Latch. Other manufacturers and types available. Consult factory.

Guide Rails.....................Supplied with .260[6.61] offset guide rails for use with Rittal 3687.832 (or equivalent) PSU guides.

Front Panel Overlay........Supplied with Lexan overlay and JE Logo. May be deleted, or supplied with customer specified logo or other information. Consult factory.

Weight ............................Approx: 1.8 lbs / 1.06 kgs.

-SAFETY-

All Models....................... Recognized to U.S. and Canadian Bi-National Standard CSA C22.2 No. 60950 / UL 60950, Third (3 rd ) Edition (cULus);

   TUV approved to TUV EN60950/A1-A4/A11. CE Marked. CB Reports available on request.


2 Total loading on all outputs not to exceed 200W.

Combined load on V1 + V2 not to exceed 38A.

3 Total loading on all outputs not to exceed 200W.

Combined load on V1 + V2 not to exceed 38A.



ORDERING INFORMATION
Call us for more details and quote.
   Return to Top | Terms & Conditions | Contact Us | Site Map | Company Info | © IBUS Corp. -2007 |